Osteotome Versus Conventional Drilling Technique for Implant Site Preparation: A Comparative Study in the Rabbit
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 32 , Issue 3
June 2012

Pages 346 (e109-e115)


Osteotome Versus Conventional Drilling Technique for Implant Site Preparation: A Comparative Study in the Rabbit


Ana Rita Nóbrega, DDS, MSc/Ana Norton, DDS, MSc/José António Silva, DDS/José Pedro Dias Silva, DDS, MSc/Fernando Morais Branco, DDS, PhD/Eduardo Anitua, DDS


PMID: 22408780
DOI: 10.11607/prd.00.1069

The aim of this research was to study the influence of the osteotome technique on insertion torque and stability values when compared with conventional surgical drilling of the implant site. A total of 20 implants (4-mm diameter, 8.5-mm long) were placed in the distal femural condyle of 10 New Zealand White rabbits. The implant sites were prepared by using either the conventional drilling technique as a control group (group A) or the osteotome technique (group B). Cutting torque and resonance frequency analyses (RFAs) were conducted at and after implant placement. The resulting values were subjected to correlation and comparative analyses between groups. Insertion torque measurements were conducted at three different levels of implant insertion: crestal, middle, and apical. Group B showed higher mean insertion torque and RFA values (P < .05). No statistically significant correlation could be observed when comparing the mean torque values with RFA values (P > .05). Bone condensation before implant insertion in low-density bone led to higher mean insertion torque and RFA values. Within the limits of this experimental study, a benefit in using the osteotome technique was observed when dealing with low-density bone. Bone condensation can improve primary stabilization of implants. (Int J Periodontics Restorative Dent 2012;32:e109–e115.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help